research use only

CYM5541 S1P Receptor agonist

Cat.No.S6552

CYM5541 (ML249) is a selective, allosteric agonist of S1P3 with an EC50 of between 72 and 132 nM and exhibits exquisite selectivity over other S1P receptor subtypes in vitro: S1P1 EC50 > 10 μM, S1P2 EC50 > 50 μM, S1P4 EC50 > 50 μM, and S1P5 EC50 > 25 μM.
CYM5541 S1P Receptor agonist Chemical Structure

Chemical Structure

Molecular Weight: 316.44

Quality Control

Batch: S655201 Ethanol]63 mg/mL]false]DMSO]32 mg/mL]false]Water]Insoluble]false Purity: 98.16%
98.16

Chemical Information, Storage & Stability

Molecular Weight 316.44 Formula

C19H28N2O2

Storage (From the date of receipt) 3 years -20°C powder
CAS No. 945128-26-7 -- Storage of Stock Solutions

Synonyms ML249 Smiles C1CCC(CC1)N(C2CCCCC2)C(=O)C3=NOC(=C3)C4CC4

Solubility

In vitro
Batch:

Ethanol : 63 mg/mL

DMSO : 32 mg/mL ( (101.12 mM) Moisture-absorbing DMSO reduces solubility. Please use fresh DMSO.)

Water : Insoluble

Molarity Calculator

Mass Concentration Volume Molecular Weight

In vivo
Batch:

In vivo Formulation Calculator (Clear solution)

Step 1: Enter information below (Recommended: An additional animal making an allowance for loss during the experiment)

mg/kg g μL

Step 2: Enter the in vivo formulation (This is only the calculator, not formulation. Please contact us first if there is no in vivo formulation at the solubility Section.)

% DMSO % % Tween 80 % ddH2O
%DMSO %

Calculation results:

Working concentration: mg/ml;

Method for preparing DMSO master liquid: mg drug pre-dissolved in μL DMSO ( Master liquid concentration mg/mL, Please contact us first if the concentration exceeds the DMSO solubility of the batch of drug. )

Method for preparing in vivo formulation: Take μL DMSO master liquid, next addμL PEG300, mix and clarify, next addμL Tween 80, mix and clarify, next add μL ddH2O, mix and clarify.

Method for preparing in vivo formulation: Take μL DMSO master liquid, next add μL Corn oil, mix and clarify.

Note: 1. Please make sure the liquid is clear before adding the next solvent.
2. Be sure to add the solvent(s) in order. You must ensure that the solution obtained, in the previous addition, is a clear solution before proceeding to add the next solvent. Physical methods such
as vortex, ultrasound or hot water bath can be used to aid dissolving.

Mechanism of Action

Targets/IC50/Ki
S1P3 [1]
References

Tech Support

Handling Instructions

Tel: +1-832-582-8158 Ext:3

If you have any other enquiries, please leave a message.

Please enter your name.
Please enter your email. Please enter a valid email address.
Please write something to us.

Signaling Pathway Map