Clinical Trials

Pfizer has sponsored multiple completed clinical trials evaluating the therapeutic potential and safety of SU14813 in oncology. These investigations include a Phase I dose-escalation clinical trial in patients with refractory solid tumors and a Phase II clinical trial assessing efficacy and safety in metastatic breast cancer. Overall, the clinical landscape for SU14813 reflects early-to-mid-phase development targeting solid malignancies.

NCT Number Recruitment Conditions Sponsor/Collaborators Start Date Phases
NCT00322517 Completed
Breast Neoplasms
Pfizer
2006-04 Phase 2
NCT00982267 Completed
Neoplasms|Solid Tumors
Pfizer
2003-12 Phase 1

(data from https://clinicaltrials.gov, updated on 2024-05-22)

Check the SU14813 product page for in-depth specifications, including solubility, stock solutions, MOA, and working concentrations.

Compliance for Clinical Use

Mechanism and Biochemical Profile

SU14813 functions as a potent multi-targeted receptor tyrosine kinase inhibitor that selectively targets VEGFR1, VEGFR2, PDGFRβ, and c-Kit, thereby blocking downstream pro-survival and angiogenic biochemical signaling pathways to suppress endothelial cell proliferation and tumor vascularization. This combined antiangiogenic and direct antitumor activity provides the mechanistic rationale for evaluating SU14813 in clinical trials for the treatment of advanced solid tumors and metastatic breast neoplasms.

Appendix RUO and cGMP Quality Standards

Quality Dimension RUO (Research Use Only) cGMP (Current Good Manufacturing Practice)
Clinical Applicability Prohibited in human clinical trials or medical diagnostics. Mandatory for human clinical trials (Phase I–III) and therapies.
Regulatory Status Non-regulated grade; exempt from drug manufacturing laws. Legally enforced by health authorities (e.g., FDA, EMA, NMPA).
Facility Environment Unclassified analytical or research laboratories. Validated Cleanrooms (ISO Class 5–8) with continuous monitoring.
Quality Control Basic purity and activity testing. Rigorous safety release testing (Sterility, Endotoxin, Mycoplasma).
Process Validation Basic equipment calibration; no process validation required. Full qualification (IQ/OQ/PQ) and complete batch records.
Quality Assurance Vendor self-declared without required formal QMS. Mandatory QA/QC unit, Change Control, CAPA, and vendor audits.
Regulatory Impact High risk of IND rejection if used as a critical raw material. Required for IND/NDA filings, supported by Drug Master Files (DMF).

Footnotes

Regulatory Note: Governed by FDA (21 CFR Parts 210/211/312), EMA (EudraLex Vol 4), ICH Guidelines (E6/Q7/Q9/Q10), and compendial standards (USP <71>/<85>/<1043>).

Note: Technical data last updated: Sep 1, 2026.