🛡️ Hazard Overview
- GHS Class: GHS06; GHS07; GHS08; GHS09
- Signal Word: Danger
- Hazard Statements: H301; H315; H317; H319; H335; H340; H350; H351; H361; H373; H411
🧤 PPE Guidelines
- Gloves: Chemical‑resistant gloves suggested
- Eye Protection: Safety goggles suggested
- Respirator: Dust respirator if dust occurs
❄️ Storage
- Storage Temp: -20°C (-4°F) Keep dry
🚑 Emergency First Aid
- For inhalation, skin, eye or ingestion exposure, please refer to full SDS Section 4.
Product identifier
- Product Name: Methyl methanesulfonate
- Catalog Number: E0609
- CAS Number: 66-27-3
- IUPAC Name: Methyl Methanesulfonate
Relevant identified uses and uses advised against
- Identified uses: For research and development use only; laboratory chemicals; manufacture of substances.
- Uses advised against: Not for pharmaceutical, household, or other unapproved uses.
Details of the supplier
- Company: Selleck Chemicals
- TollFree: +1 877 796-6397
- Tel: +1 832 582-8158
- Fax: +1 832 582-8590
Emergency telephone number
- Emergency phone #: +1 832 582-8158
2.1 GHS classification in accordance with 29 CFR 1910 (OSHA HCS):
Acute toxicity (oral): Category 3. H301
Skin irritation: Category 2. H315
Skin sensitization: Category 1. H317
Serious eye irritation: Category 2. H319
Specific target organ toxicity (single exposure): Category 3. H335
Germ cell mutagenicity: Category 1. H340
Carcinogenicity: Category 1. H350
Carcinogenicity: Category 2. H351
Reproductive toxicity: Category 2. H361
Specific target organ toxicity (repeated exposure): Category 2. H373
Chronic aquatic toxicity: Category 2. H411
2.2 GHS Label elements, including precautionary statements
Hazard Pictogram(s):
![]()
Signal Word:
Danger
Hazard statement(s):
H301: Toxic if swallowed
H315: Causes skin irritation
H317: May cause an allergic skin reaction
H319: Causes serious eye irritation
H335: May cause respiratory irritation
H340: May cause genetic defects
H350: May cause cancer
H351: Suspected of causing cancer
H361: Suspected of damaging fertility or the unborn child
H373: May causes damage to organs through prolonged or repeated exposure
H411: Toxic to aquatic life with long lasting effects
Precautionary statement(s):
Prevention:
P203: Obtain, read and follow all safety instructions before use.
P260: Do not breathe dust/fume/gas/mist/vapors/spray.
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P264: Wash hands thoroughly after handling.
P264+P265: Wash hands thoroughly after handling. Do not touch eyes.
P270: Do not eat, drink or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P272: Contaminated work clothing should not be allowed out of the workplace.
P273: Avoid release to the environment.
P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
Response:
P301+P316: IF SWALLOWED: Get emergency medical help immediately.
P302+P352: IF ON SKIN: wash with plenty of water.
P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351: IF IN EYES: Rinse cautiously with water for several minutes.
P318: if exposed or concerned, get medical advice.
P319: Get medical help if you feel unwell.
P321: Specific treatment (see information on this label and safety datasheet)).
P330: Rinse mouth.
P332+P317: If skin irritation occurs: Get medical help.
P333+P317: If skin irritation or rash occurs: Get medical help.
P337+P317: If eye irritation persists: Get medical help.
P338: Remove contact lenses, if present and easy to do. Continue rinsing.
P362+P364: Take off contaminated clothing and wash it before reuse.
P391: Collect spillage.
Storage:
P403+P233: Store in a well-ventilated place. Keep container tightly closed.
P405: Store locked up.
Disposal:
P501: P501 Dispose of contents/ container to an approved waste disposal plant.
2.3 Other hazards
None.
3.1 Substances
Product name: Methyl methanesulfonate
CAS Number: 66-27-3
PubChem CID: 4156
Molecular formula: C2H6O3S
Molecular weight: 110.13 g/mol
IUPAC name: methyl methanesulfonate
3.2 Mixtures
Not applicable (pure substance).
4.1 Description of first aid measures
Inhalation: INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. IMMEDIATELY call a physician and be prepared to transport the victim to a hospital even if no symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater
Skin contact: SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. IMMEDIATELY call a hospital or poison control center even if no symptoms (such as redness or irritation) develop. IMMEDIATELY transport the victim to a hospital for treatment after washing the affected areas.
Eye contact: EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.
Ingestion: INGESTION: DO NOT INDUCE VOMITING. Corrosive chemicals will destroy the membranes of the mouth, throat, and esophagus and, in addition, have a high risk of being aspirated into the victim's lungs during vomiting which increases the medical problems. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. IMMEDIATELY transport the victim to a hospital. If the victim is convulsing or unconscious, d
4.2 Most important symptoms and effects, both acute and delayed
See Section 11 (Toxicological Information).
4.3 Indication of any immediate medical attention and special treatment needed
Treat symptomatically. Contact a poison control center or physician for severe exposure.
5.1 Extinguishing media
Suitable: Water spray, dry chemical, carbon dioxide (CO2), alcohol-resistant foam.
Unsuitable: None known.
5.2 Specific hazards arising from the substance or mixture
Fires involving this material can be controlled with a dry chemical, carbon dioxide or Halon extinguisher. (NTP, 1992)
5.3 Advice for firefighters
Wear self-contained breathing apparatus (SCBA) and full protective clothing.
Fight fire from upwind. Cool containers with water spray until fire is extinguished.
Flash point: 220 °F (NTP, 1992)
6.1 Personal precautions, protective equipment and emergency procedures
Wear appropriate personal protective equipment (see Section 8).
Avoid breathing dust/vapor. Ensure adequate ventilation.
Evacuate personnel to safe areas. Keep people away from and upwind of spill.
WARNING: Highly toxic — only trained personnel should handle spills.
6.2 Environmental precautions
Prevent product from entering drains, waterways, or soil.
Contain spill with inert absorbent material.
6.3 Methods and materials for containment and cleaning up
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.
SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
PRECAUTIONS FOR "CARCINOGENS": A high-efficiency particulate arrestor (HEPA) or charcoal filters can be used to minimize amt of carcinogen in exhausted air ventilated safety cabinets, lab hoods, glove boxes or animal rooms ... Filter housing that is designed so that used filters can be transferred into plastic bag without contaminating maintenance staff is avail commercially. Filters should be placed in plastic bags immediately after removal ... The plastic bag should be sealed immediately ... The sealed bag should be labelled properly ... Waste liquids ... should be placed or collected in proper containers for disposal. The lid should be secured & the bottles properly labelled. Once filled, bottles should be placed in plastic bag, so that outer surface ... is not contaminated ... The plastic bag should also be sealed & labelled. ... Broken glassware ... should be decontaminated by solvent extraction, by chemical destruction, or in specially designed incinerators. /Chemical Carcinogens/
SRP: The most favorable course of action is to use an alternative chemical product with less inherent propensity for occupational exposure or environmental contamination. Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in soil or water; effects on animal, aquatic, and plant life; and conformance with environmental and public health regulations.
PRECAUTIONS FOR "CARCINOGENS": There is no universal method of disposal that has been proved satisfactory for all carcinogenic compounds & specific methods of chem destruction ... published have not been tested on all kinds of carcinogen-containing waste. ... summary of avail methods & recommendations ... /given/ must be treated as guide only. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Incineration may be only feasible method for disposal of contaminated laboratory waste from biological expt. However, not all incinerators are suitable for this purpose. The most efficient type ... is probably the gas-fired type, in which a first-stage combustion with a less than stoichiometric air:fuel ratio is followed by a second stage with excess air. Some ... are designed to accept ... aqueous & organic-solvent solutions, otherwise it is necessary ... to absorb soln onto suitable combustible material, such as sawdust. Alternatively, chem destruction may be used, esp when small quantities ... are to be destroyed in laboratory. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": HEPA (high-efficiency particulate arrestor) filters ... can be disposed of by incineration. For spent charcoal filters, the adsorbed material can be stripped off at high temp & carcinogenic wastes generated by this treatment conducted to & burned in an incinerator. ... LIQUID WASTE: ... Disposal should be carried out by incineration at temp that ... ensure complete combustion. SOLID WASTE: Carcasses of lab animals, cage litter & misc solid wastes ... should be disposed of by incineration at temp high enough to ensure destruction of chem carcinogens or their metabolites. /Chemical Carcinogens/
For more Disposal Methods (Complete) data for METHYL METHANESULFONATE (7 total), please visit the HSDB record page.
PRECAUTIONS FOR "CARCINOGENS": Smoking, drinking, eating, storage of food or of food & beverage containers or utensils, & the application of cosmetics should be prohibited in any laboratory. All personnel should remove gloves, if worn, after completion of procedures in which carcinogens have been used. They should ... wash ... hands, preferably using dispensers of liq detergent, & rinse ... thoroughly. Consideration should be given to appropriate methods for cleaning the skin, depending on nature of the contaminant. No standard procedure can be recommended, but the use of organic solvents should be avoided. Safety pipettes should be used for all pipetting. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": In animal laboratory, personnel should remove their outdoor clothes & wear protective suits (preferably disposable, one-piece & close-fitting at ankles & wrists), gloves, hair covering & overshoes. ... Clothing should be changed daily but ... discarded immediately if obvious contamination occurs ... /also,/ workers should shower immediately. In chemical laboratory, gloves & gowns should always be worn ... however, gloves should not be assumed to provide full protection. Carefully fitted masks or respirators may be necessary when working with particulates or gases, & disposable plastic aprons might provide addnl protection. If gowns are of distinctive color, this is a reminder that they should not be worn outside of lab. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Operations connected with synth & purification ... should be carried out under well-ventilated hood. Analytical procedures ... should be carried out with care & vapors evolved during ... procedures should be removed. ... Expert advice should be obtained before existing fume cupboards are used ... & when new fume cupboards are installed. It is desirable that there be means for decreasing the rate of air extraction, so that carcinogenic powders can be handled without ... powder being blown around the hood. Glove boxes should be kept under negative air pressure. Air changes should be adequate, so that concn of vapors of volatile carcinogens will not occur. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Vertical laminar-flow biological safety cabinets may be used for containment of in vitro procedures ... provided that the exhaust air flow is sufficient to provide an inward air flow at the face opening of the cabinet, & contaminated air plenums that are under positive pressure are leak-tight. Horizontal laminar-flow hoods or safety cabinets, where filtered air is blown across the working area towards the operator, should never be used ... Each cabinet or fume cupboard to be used ... should be tested before work is begun (eg, with fume bomb) & label fixed to it, giving date of test & avg air-flow measured. This test should be repeated periodically & after any structural changes. /Chemical Carcinogens/
For more Preventive Measures (Complete) data for METHYL METHANESULFONATE (9 total), please visit the HSDB record page.
7.1 Precautions for safe handling
SMALL SPILLS AND LEAKAGE: If you should spill this chemical, use absorbent paper to pick up all liquid spill material. Seal the absorbent paper, as well as any of your clothing which may be contaminated, in a vapor-tight plastic bag for eventual disposal. Wash any surfaces you may have contaminated with a soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned.
STORAGE PRECAUTIONS: You should store this material at ambient temperatures and away from oxidizers. (NTP, 1992)
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practical to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. /Chemical Carcinogens/
7.2 Conditions for safe storage, including any incompatibilities
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practical to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. /Chemical Carcinogens/
Store away from incompatible materials (see Section 10).
[Note: Specific storage temperature not available in public databases. Refer to supplier Certificate of Analysis (COA) for exact storage conditions.]
Store in original container. Keep upright to prevent leakage.
8.1 Exposure controls
8.1.1 Occupational exposure limits (OEL)
OSHA PEL: Not established.
ACGIH TLV: Not established.
NIOSH REL: Not established.
No occupational exposure limit values are established for this substance.
Use the lowest feasible exposure level (ALARA principle).
8.1.2 Appropriate engineering controls
Use only in a chemical fume hood or with local exhaust ventilation.
Ensure adequate ventilation to keep airborne concentrations below exposure limits.
8.2 Individual protection measures
8.2.1 Eye/face protection
Wear chemical safety goggles.
8.2.2 Skin protection
Wear protective gloves. Recommended material: Nitrile rubber.
Wear suitable protective clothing (lab coat).
8.2.3 Respiratory protection
Use NIOSH-approved dust/mist respirator (N95 or higher) if ventilation is inadequate.
8.2.4 Thermal hazards
Not applicable.
9.1 Information on basic physical and chemical properties
a) Appearance: Methyl methanesulfonate is a colorless to amber liquid. (NTP, 1992)
b) Odor: No data available
c) Odor threshold: No data available
d) pH: No data available
e) Melting point/freezing point: 68 °F (NTP, 1992)
f) Initial boiling point and boiling range: 396 to 397 °F at 760 mmHg (NTP, 1992)
g) Flash point: 220 °F (NTP, 1992)
h) Evaporation rate: No data available
i) Flammability (solid, gas): No data available
j) Upper/lower flammability or explosive limits: No data available
k) Vapor pressure: 0.31 [mmHg]
l) Vapor density: No data available
m) Relative density: 1.2943 at 68 °F (NTP, 1992) - Denser than water; will sink
n) Water solubility: greater than or equal to 100 mg/mL at 73 °F (NTP, 1992)
o) Partition coefficient: n-octanol/water: Log P (n-octanol/water): -0.4
p) Auto-ignition temperature: No data available
q) Decomposition temperature: No data available
r) Viscosity: No data available
s) Explosive properties: No data available
t) Oxidizing properties: No data available
9.2 Other information
Topological Polar Surface Area (TPSA): 51.8 Ų
Complexity: 105
10.1 Reactivity
No specific reactivity hazards identified under normal handling conditions.
10.2 Chemical stability
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
No hazardous reactions under normal conditions.
10.4 Conditions to avoid
Avoid heat, sparks, open flames, direct sunlight, and moisture.
Avoid strong oxidizing agents, strong acids, and strong bases.
10.5 Incompatible materials
Strong oxidizing agents, strong acids, strong bases.
10.6 Hazardous decomposition products
Thermal decomposition may produce: Carbon monoxide (CO), Carbon dioxide (CO₂), Sulfur oxides (SOx).
See also Section 5 (Fire-fighting measures) for combustion products.
11.1 Information on toxicological effects
Acute toxicity:
No acute toxicity data available.
Skin corrosion/irritation:
Causes skin irritation (H315).
Serious eye damage/eye irritation:
Causes serious eye irritation (H319).
Respiratory or skin sensitization:
May cause an allergic skin reaction (H317).
Germ cell mutagenicity:
May cause genetic defects (H340).
Carcinogenicity:
May cause cancer (H350).
Reproductive toxicity:
Suspected of damaging fertility or the unborn child (H361).
Specific target organ toxicity (single exposure):
H373
Specific target organ toxicity (repeated exposure):
No data available.
Aspiration hazard:
No data available.
11.2 Additional information
Carcinogen classification:
Methyl methanesulfonate
Group 2A: Probably carcinogenic to humans
Volume 7: (1974) Some Anti-thyroid and Related Substances, Nitrofurans and Industrial Chemicals
Volume Sup 7: Overall Evaluations of Carcinogenicity: An Updating of IARC Monographs Volumes 1 to 42, 1987; 440 pages; ISBN 92-832-1411-0 (out of print)
Volume 71: (1999) Re-evaluation of Some Organic Chemicals, Hydrazine and Hydrogen Peroxide (Part 1, Part 2, Part 3)
1999
1998
NB Overall evaluation upgraded to Group 2A with supporting
Data source: Hazardous Substances Data Bank (HSDB) via PubChem.
12.1 Toxicity
EC50; Species: Oryzias latipes (Medaka, high-eyes, embryo 66 hr postfertilization); Conditions: freshwater, static, 20 °C; Concentration: 12.5 mmol/L for 2 hr (95% confidence interval: 10.9-14.0 mmol/L); Effect: growth
LC50; Species: Oryzias latipes (Medaka, high-eyes, embryo 66 hr postfertilization); Conditions: freshwater, static, 20 °C; Concentration: 15.8 mmol/L for 2 hr (95% confidence interval: 14.0-17.8 mmol/L)
LC50 Eisenia fetida (earthworm, mature, weight 370-450 mg) direct application 1-10 ug/sq cm for 48 hr
5.50e+00
2.30e+01
1.00e-01
4.40e-01
7.90e-01
4.00e+01
1.60e-04
9.90e-02
2.8e-05
Volatile
Mutagen
1
0.1
5.50e+02
2.30e+03
1.00e+01
4.40e+01
7.90e+01
4.00e+01
9.90e-02
2.8e-05
Volatile
Mutagen
1
0.1
Methyl methanesulfonate's former production and use as a research chemical may have resulted in its limited release to the environment through various waste streams. If released to air, an estimated vapor pressure of 0.3 mm Hg at 25 °C indicates methyl methanesulfonate will exist solely as a vapor in the atmosphere. Vapor-phase methyl methanesulfonate will be degraded in the atmosphere by reaction with photochemically-produced hydroxyl radicals; the half-life for this reaction in air is estimated to be 70 days. Methyl methanesulfonate does not contain chromophores that absorb at wavelengths >290 nm and therefore is not expected to be susceptible to direct photolysis by sunlight. If released to soil, methyl methanesulfonate is expected to have very high mobility based u
12.2 Persistence and degradability
No data available.
12.3 Bioaccumulative potential
Log P (n-octanol/water): -0.4
Low potential for bioaccumulation (Log P < 3).
12.4 Mobility in soil
No data available.
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available.
12.6 Other adverse effects
This substance is classified as hazardous to the aquatic environment.
13.1 Waste treatment methods
Waste Treatment Methods: Waste material must be disposed of in accordance with national and local regulations. Leave chemicals in original containers and do not mix with other waste. Handle uncleaned containers in the same manner as the product itself.
14.1 UN number
Not regulated as dangerous goods (research quantities typically exempt).
14.2 UN proper shipping name
Not subject to transport regulations (small quantities for research use).
14.3 Transport hazard class(es)
Not classified as dangerous goods for transport (research quantities).
DOT label: Corrosive Poison
14.4 Packing group
Not applicable (not regulated as dangerous goods in typical research quantities).
14.5 Environmental hazards
Marine pollutant: Yes (classified as environmentally hazardous per GHS).
14.6 Special precautions for user
Transport in original packaging. Ensure containers are tightly sealed.
For bulk or commercial quantities, consult applicable transport regulations (DOT, IATA, IMDG).
14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not applicable.
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
US EPA / TSCA: Subject to EPA TSCA regulations
EU ECHA / REACH: Registered (REACH Active)
SARA 302 Components:
No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components:
This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards:
Acute (short-term) health hazard
Chronic (long-term) health hazard
Environmental hazard
Massachusetts Right To Know Components:
This material contains components subject to the Massachusetts Right to Know Act. See Section 2 for hazard classification.
Pennsylvania Right To Know Components:
This material contains components subject to the Pennsylvania Right to Know Act. See Section 2 for hazard classification.
New Jersey Right To Know Components:
This material contains components subject to the New Jersey Right to Know Act. See Section 2 for hazard classification.
California Prop. 65 Components:
This product does not contain any chemicals known to the State of California to cause cancer, birth defects, or any other reproductive harm.
Other regulatory listings:
- The Australian Inventory of Industrial Chemicals: Chemical: Methanesulfonic acid, methyl ester
- California Safe Cosmetics Program (CSCP) Reportable Ingredient: Hazard Traits - Carcinogenicity Authoritative List - IARC Carcinogens - 2A; NTP RoC - reasonable; Prop 65 Report - regardless of intended function of ingredient in the product
15.2 Chemical safety assessment
A chemical safety assessment has not been carried out for this substance.
For research-use-only compounds, no CSA is required under REACH Annex I.
Revision Date: 2026/09/08
Further Information: The information provided is believed to be correct but is not exhaustive and should be used only as a guideline based on current knowledge. It does not represent a guarantee of the properties of the product. Selleck Chemicals Corporation and its Affiliates shall not be held liable for any damage resulting from handling or contact with the product.
- Methyl methanesulfonate Clinical Trials
- Methyl methanesulfonate Solubility in DMSO
- Methyl methanesulfonate Stock Solution
- Methyl methanesulfonate Storage
- Methyl methanesulfonate Stability
- Methyl methanesulfonate Molecular Weight
- Methyl methanesulfonate SMILES
- Methyl methanesulfonate CAS Number
- Methyl methanesulfonate Chemical Structure (2D and 3D)