Download SDS
CAS No.: 396-01-0
Check the Triamterene product page for in-depth specifications, including solubility, stock solutions, MOA, and working concentrations.

Quick Safety Reference

🛡️ Hazard Overview

  • GHS Class: GHS07
  • Signal Word: Warning
  • Hazard Statements: H302; H315; H319; H335

🧤 PPE Guidelines

  • Gloves: Chemical‑resistant gloves suggested
  • Eye Protection: Safety goggles suggested
  • Respirator: Dust respirator if dust occurs

❄️ Storage

  • Storage Temp: -20°C (-4°F) Keep dry

🚑 Emergency First Aid

  • For inhalation, skin, eye or ingestion exposure, please refer to full SDS Section 4.

GHS 16 Safety Standard Sections

Product identifier

  • Product Name: Triamterene
  • Catalog Number: S4080
  • CAS Number: 396-01-0
  • IUPAC Name: 2,4,7-Pteridinetriamine, 6-phenyl-

Relevant identified uses and uses advised against

  • Identified uses: For research and development use only; laboratory chemicals; manufacture of substances.
  • Uses advised against: Not for pharmaceutical, household, or other unapproved uses.

Details of the supplier

  • Company: Selleck Chemicals
  • TollFree: +1 877 796-6397
  • Tel: +1 832 582-8158
  • Fax: +1 832 582-8590

Emergency telephone number

  • Emergency phone #: +1 832 582-8158

2.1 GHS classification in accordance with 29 CFR 1910 (OSHA HCS):
Acute toxicity (oral): Category 4. H302
Skin irritation: Category 2. H315
Serious eye irritation: Category 2. H319
Specific target organ toxicity (single exposure): Category 3. H335

2.2 GHS Label elements, including precautionary statements
Hazard Pictogram(s):
GHS07
Signal Word:
Warning
Hazard statement(s):
H302: Harmful if swallowed
H315: Causes skin irritation
H319: Causes serious eye irritation
H335: May cause respiratory irritation
Precautionary statement(s):
Prevention:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P264: Wash hands thoroughly after handling.
P264+P265: Wash hands thoroughly after handling. Do not touch eyes.
P270: Do not eat, drink or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
Response:
P301+P317: IF SWALLOWED: Get medical help.
P302+P352: IF ON SKIN: wash with plenty of water.
P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351: IF IN EYES: Rinse cautiously with water for several minutes.
P319: Get medical help if you feel unwell.
P321: Specific treatment (see information on this label and safety datasheet)).
P330: Rinse mouth.
P332+P317: If skin irritation occurs: Get medical help.
P337+P317: If eye irritation persists: Get medical help.
P338: Remove contact lenses, if present and easy to do. Continue rinsing.
P362+P364: Take off contaminated clothing and wash it before reuse.
Storage:
P403+P233: Store in a well-ventilated place. Keep container tightly closed.
P405: Store locked up.
Disposal:
P501: P501 Dispose of contents/ container to an approved waste disposal plant.

2.3 Other hazards
None.

3.1 Substances
Product name: Triamterene
CAS Number: 396-01-0
PubChem CID: 5546
Molecular formula: C12H11N7
Molecular weight: 253.26 g/mol
IUPAC name: 6-phenylpteridine-2,4,7-triamine

3.2 Mixtures
Not applicable (pure substance).

4.1 Description of first aid measures
Inhalation: INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to t
Skin contact: SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. If symptoms such as redness or irritation develop, IMMEDIATELY call a physician and be prepared to transport the victim to a hospital for treatment.
Eye contact: EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. If symptoms (such as redness or irritation) develop, immediately transport the victim to a hospital.
Ingestion: INGESTION: DO NOT INDUCE VOMITING. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. Be prepared to transport the victim to a hospital if advised by a physician. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. IMMEDIATELY transport

4.2 Most important symptoms and effects, both acute and delayed
See Section 11 (Toxicological Information).

4.3 Indication of any immediate medical attention and special treatment needed
Treat symptomatically. Contact a poison control center or physician for severe exposure.

5.1 Extinguishing media
Suitable: Water spray, dry chemical, carbon dioxide (CO2), alcohol-resistant foam.
Unsuitable: None known.

5.2 Specific hazards arising from the substance or mixture
Fires involving this material can be controlled with a dry chemical, carbon dioxide or Halon extinguisher. (NTP, 1992)
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Advice for firefighters: Wear self contained breathing apparatus for fire fighting if necessary.

5.3 Advice for firefighters
Wear self-contained breathing apparatus (SCBA) and full protective clothing.
Fight fire from upwind. Cool containers with water spray until fire is extinguished.

6.1 Personal precautions, protective equipment and emergency procedures
Wear appropriate personal protective equipment (see Section 8).
Avoid breathing dust/vapor. Ensure adequate ventilation.
Evacuate personnel to safe areas. Keep people away from and upwind of spill.

6.2 Environmental precautions
Prevent product from entering drains, waterways, or soil.
Contain spill with inert absorbent material.

6.3 Methods and materials for containment and cleaning up
PRECAUTIONS FOR "CARCINOGENS": A high-efficiency particulate arrestor (HEPA) or charcoal filters can be used to minimize amt of carcinogen in exhausted air ventilated safety cabinets, lab hoods, glove boxes or animal rooms ... Filter housing that is designed so that used filters can be transferred into plastic bag without contaminating maintenance staff is avail commercially. Filters should be placed in plastic bags immediately after removal ... The plastic bag should be sealed immediately ... The sealed bag should be labelled properly ... Waste liquids ... should be placed or collected in proper containers for disposal. The lid should be secured & the bottles properly labelled. Once filled, bottles should be placed in plastic bag, so that outer surface ... is not contaminated ... The plastic bag should also be sealed & labelled. ... Broken glassware ... should be decontaminated by solvent extraction, by chemical destruction, or in specially designed incinerators. /Chemical Carcinogens/
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. Environmental precautions: Do not let product enter drains. Methods and materials for containment and cleaning up: Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
SRP: Expired or waste pharmaceuticals shall carefully take into consideration applicable DEA, EPA, and FDA regulations. It is not appropriate to dispose by flushing the pharmaceutical down the toilet or discarding to trash. If possible return the pharmaceutical to the manufacturer for proper disposal being careful to properly label and securely package the material. Alternatively, the waste pharmaceutical shall be labeled, securely packaged and transported by a state licensed medical waste contractor to dispose by burial in a licensed hazardous or toxic waste landfill or incinerator.
Product: Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber; Contaminated packaging: Dispose of as unused product.
PRECAUTIONS FOR "CARCINOGENS": There is no universal method of disposal that has been proved satisfactory for all carcinogenic compounds & specific methods of chem destruction ... published have not been tested on all kinds of carcinogen-containing waste. ... summary of avail methods & recommendations ... /given/ must be treated as guide only. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Incineration may be only feasible method for disposal of contaminated laboratory waste from biological expt. However, not all incinerators are suitable for this purpose. The most efficient type ... is probably the gas-fired type, in which a first-stage combustion with a less than stoichiometric air:fuel ratio is followed by a second stage with excess air. Some ... are designed to accept ... aqueous & organic-solvent solutions, otherwise it is necessary ... to absorb soln onto suitable combustible material, such as sawdust. Alternatively, chem destruction may be used, esp when small quantities ... are to be destroyed in laboratory. /Chemical Carcinogens/
For more Disposal Methods (Complete) data for Triamterene (7 total), please visit the HSDB record page.
PRECAUTIONS FOR "CARCINOGENS": Smoking, drinking, eating, storage of food or of food & beverage containers or utensils, & the application of cosmetics should be prohibited in any laboratory. All personnel should remove gloves, if worn, after completion of procedures in which carcinogens have been used. They should ... wash ... hands, preferably using dispensers of liq detergent, & rinse ... thoroughly. Consideration should be given to appropriate methods for cleaning the skin, depending on nature of the contaminant. No standard procedure can be recommended, but the use of organic solvents should be avoided. Safety pipettes should be used for all pipetting. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": In animal laboratory, personnel should remove their outdoor clothes & wear protective suits (preferably disposable, one-piece & close-fitting at ankles & wrists), gloves, hair covering & overshoes. ... Clothing should be changed daily but ... discarded immediately if obvious contamination occurs ... /also,/ workers should shower immediately. In chemical laboratory, gloves & gowns should always be worn ... however, gloves should not be assumed to provide full protection. Carefully fitted masks or respirators may be necessary when working with particulates or gases, & disposable plastic aprons might provide addnl protection. If gowns are of distinctive color, this is a reminder that they should not be worn outside of lab. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Operations connected with synth & purification ... should be carried out under well-ventilated hood. Analytical procedures ... should be carried out with care & vapors evolved during ... procedures should be removed. ... Expert advice should be obtained before existing fume cupboards are used ... & when new fume cupboards are installed. It is desirable that there be means for decreasing the rate of air extraction, so that carcinogenic powders can be handled without ... powder being blown around the hood. Glove boxes should be kept under negative air pressure. Air changes should be adequate, so that concn of vapors of volatile carcinogens will not occur. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Vertical laminar-flow biological safety cabinets may be used for containment of in vitro procedures ... provided that the exhaust air flow is sufficient to provide an inward air flow at the face opening of the cabinet, & contaminated air plenums that are under positive pressure are leak-tight. Horizontal laminar-flow hoods or safety cabinets, where filtered air is blown across the working area towards the operator, should never be used ... Each cabinet or fume cupboard to be used ... should be tested before work is begun (eg, with fume bomb) & label fixed to it, giving date of test & avg air-flow measured. This test should be repeated periodically & after any structural changes. /Chemical Carcinogens/
For more Preventive Measures (Complete) data for Triamterene (14 total), please visit the HSDB record page.

7.1 Precautions for safe handling
SMALL SPILLS AND LEAKAGE: If you spill this chemical, dampen the solid spill material with 5% ammonium hydroxide, then transfer the dampened material to a suitable container. Use absorbent paper dampened with 5% ammonium hydroxide to pick up any remaining material. Your contaminated clothing and the absorbent paper should be sealed in a vapor-tight plastic bag for eventual disposal. Wash all contaminated surfaces with 5% ammonium hydroxide followed by washing with a soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned.
STORAGE PRECAUTIONS: You should protect this chemical from exposure to light. Keep the container tightly closed under an inert atmosphere, and store under refrigerated temperatures. (NTP, 1992)
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practical to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. /Chemical Carcinogens/
Keep container tightly closed in a dry and well-ventilated place.

7.2 Conditions for safe storage, including any incompatibilities
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practical to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. /Chemical Carcinogens/
Keep container tightly closed in a dry and well-ventilated place.
Store away from incompatible materials (see Section 10).
[Note: Specific storage temperature not available in public databases. Refer to supplier Certificate of Analysis (COA) for exact storage conditions.]

8.1 Exposure controls
8.1.1 Occupational exposure limits (OEL)
OSHA PEL: Not established.
ACGIH TLV: Not established.
NIOSH REL: Not established.
No occupational exposure limit values are established for this substance.
Use the lowest feasible exposure level (ALARA principle).

8.1.2 Appropriate engineering controls
Use only in a chemical fume hood or with local exhaust ventilation.
Ensure adequate ventilation to keep airborne concentrations below exposure limits.

8.2 Individual protection measures
8.2.1 Eye/face protection
Wear chemical safety goggles.
8.2.2 Skin protection
Wear protective gloves. Recommended material: Nitrile rubber.
Wear suitable protective clothing (lab coat).
8.2.3 Respiratory protection
Use NIOSH-approved dust/mist respirator (N95 or higher) if ventilation is inadequate.
8.2.4 Thermal hazards
Not applicable.

9.1 Information on basic physical and chemical properties
a) Appearance: Triamterene appears as odorless yellow powder or crystalline solid. Melting point 316 °C. Almost tasteless at first and with a slightly bitter aftertaste. Acidified solutions give a blue fluorescence. Used as a diuretic drug.
b) Odor: Odorless
c) Odor threshold: No data available
d) pH: No data available
e) Melting point/freezing point: 601 °F (NTP, 1992)
f) Initial boiling point and boiling range: No data available
g) Flash point: No data available
h) Evaporation rate: No data available
i) Flammability (solid, gas): No data available
j) Upper/lower flammability or explosive limits: No data available
k) Vapor pressure: No data available
l) Vapor density: No data available
m) Relative density: No data available
n) Water solubility: less than 1 mg/mL at 68 °F (NTP, 1992)
o) Partition coefficient: n-octanol/water: Log P (n-octanol/water): 1
p) Auto-ignition temperature: No data available
q) Decomposition temperature: No data available
r) Viscosity: No data available
s) Explosive properties: No data available
t) Oxidizing properties: No data available

9.2 Other information
Topological Polar Surface Area (TPSA): 130 Ų
Complexity: 306

10.1 Reactivity
No specific reactivity hazards identified under normal handling conditions.

10.2 Chemical stability
Stable under recommended storage conditions.

10.3 Possibility of hazardous reactions
No hazardous reactions under normal conditions.

10.4 Conditions to avoid
Avoid heat, sparks, open flames, direct sunlight, and moisture.
Avoid strong oxidizing agents, strong acids, and strong bases.

10.5 Incompatible materials
Incompatible materials: Strong oxidizing agents.

10.6 Hazardous decomposition products
Thermal decomposition may produce: Carbon monoxide (CO), Carbon dioxide (CO₂), Nitrogen oxides (NOx).
See also Section 5 (Fire-fighting measures) for combustion products.

11.1 Information on toxicological effects
Acute toxicity:
No acute toxicity data available.
Skin corrosion/irritation:
Causes skin irritation (H315).
Serious eye damage/eye irritation:
Causes serious eye irritation (H319).
Respiratory or skin sensitization:
No data available.
Germ cell mutagenicity:
No data available.
Carcinogenicity:
No data available.
Reproductive toxicity:
No data available.
Specific target organ toxicity (single exposure):
No data available.
Specific target organ toxicity (repeated exposure):
No data available.
Aspiration hazard:
No data available.

11.2 Additional information
Carcinogen classification:
Triamterene
Group 2B: Possibly carcinogenic to humans
Volume 108: (2016) Some Drugs and Herbal Products
2016
2013
Triamterene
TR-420: Toxicology and Carcinogenesis Studies of Triamterene (CASRN 396-01-0) in F344/N Rats and B6C3F1 Mice (Feed Studies) (1993 )
11/21/91
Equivocal Evidence
No Evidence
Some Evidence
Some Evidence
Under the conditions of these 2-year feed studies, there was equivocal evidence of carcinogenic activity of triamterene in male F344/N rats based on a marginal increase in t
Data source: Hazardous Substances Data Bank (HSDB) via PubChem.

12.1 Toxicity
Triamterene's production and administration as a medication may result in its release to the environment through various waste streams. If released to air, an estimated vapor pressure of 1.1X10-11 mm Hg at 25 °C indicates triamterene will exist solely in the particulate phase in the atmosphere. Particulate-phase triamterene will be removed from the atmosphere by wet and dry deposition. Triamterene absorbs UV light at 356 nm and, therefore, may be susceptible to direct photolysis by sunlight. If released to soil, triamterene is expected to be immobile based upon an estimated Koc of 1.5X10+5. The pKa of triamterene is 6.2, indicating that this compound will exist partially in the cation form in the environment and cations generally adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts. Volatilization of the neutral species from moist soil surfaces is not expected to be an important fate process based upon an estimated Henry's Law constant of 1.9X10-18 atm-cu m/mole. Triamterene is not expected to volatilize from dry soil surfaces based upon its vapor pressure. Biodegradation data in soil or water were not available. If released into water, triamterene is expected to adsorb to suspended solids and sediment based upon the estimated Koc. Volatilization of the neutral species from water surfaces is not expected to be an important fate process based upon this compound's estimated Henry's Law constant. The pKa indicates triamterene will exis

12.2 Persistence and degradability
No data available.

12.3 Bioaccumulative potential
Log P (n-octanol/water): 1
Low potential for bioaccumulation (Log P < 3).

12.4 Mobility in soil
No data available.

12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available.

12.6 Other adverse effects
No other adverse ecological effects identified.

13.1 Waste treatment methods
Waste Treatment Methods: Waste material must be disposed of in accordance with national and local regulations. Leave chemicals in original containers and do not mix with other waste. Handle uncleaned containers in the same manner as the product itself.

14.1 UN number
Not regulated as dangerous goods (research quantities typically exempt).

14.2 UN proper shipping name
Not subject to transport regulations (small quantities for research use).

14.3 Transport hazard class(es)
Not classified as dangerous goods for transport (research quantities).

14.4 Packing group
Not applicable (not regulated as dangerous goods in typical research quantities).

14.5 Environmental hazards
Marine pollutant: No (not classified as environmentally hazardous per GHS).

14.6 Special precautions for user
Transport in original packaging. Ensure containers are tightly sealed.
For bulk or commercial quantities, consult applicable transport regulations (DOT, IATA, IMDG).

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not applicable.

15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
US EPA / TSCA: Subject to EPA TSCA regulations
EU ECHA / REACH: Not available in public databases.

SARA 302 Components:
No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components:
This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards:
Acute (short-term) health hazard

Massachusetts Right To Know Components:
This material contains components subject to the Massachusetts Right to Know Act. See Section 2 for hazard classification.
Pennsylvania Right To Know Components:
This material contains components subject to the Pennsylvania Right to Know Act. See Section 2 for hazard classification.
New Jersey Right To Know Components:
This material contains components subject to the New Jersey Right to Know Act. See Section 2 for hazard classification.

California Prop. 65 Components:
This product does not contain any chemicals known to the State of California to cause cancer, birth defects, or any other reproductive harm.

Other regulatory listings:
- California Safe Cosmetics Program (CSCP) Reportable Ingredient: Hazard Traits - Carcinogenicity Authoritative List - IARC Carcinogens - 2B; Prop 65 Report - regardless of intended function of ingredient in the product
- FDA Requirements: The Approved Drug Products with Therapeutic Equivalence Evaluations identifies currently marketed prescription drug products, including triamterene, approved on the basis of safety and effectiveness by FDA under sections 505 of the Federal Food, Drug, and Cosmetic Act.
Manufacturers, packers, and di

15.2 Chemical safety assessment
A chemical safety assessment has not been carried out for this substance.
For research-use-only compounds, no CSA is required under REACH Annex I.

Revision Date: 2026/09/09
Further Information: The information provided is believed to be correct but is not exhaustive and should be used only as a guideline based on current knowledge. It does not represent a guarantee of the properties of the product. Selleck Chemicals Corporation and its Affiliates shall not be held liable for any damage resulting from handling or contact with the product.

Note: Technical data last updated: Sep 1, 2026.