🛡️ Hazard Overview
- GHS Class: None
- Signal Word: Not applicable
- Hazard Statements: None
🧤 PPE Guidelines
- Gloves: Chemical‑resistant gloves suggested
- Eye Protection: Safety goggles suggested
- Respirator: Dust respirator if dust occurs
❄️ Storage
- Storage Temp: -20°C (-4°F) Keep dry
🚑 Emergency First Aid
- For inhalation, skin, eye or ingestion exposure, please refer to full SDS Section 4.
Product identifier
- Product Name: Stearamide
- Catalog Number: E4416
- CAS Number: 124-26-5
- IUPAC Name: Octadecanamide
Relevant identified uses and uses advised against
- Identified uses: For research and development use only; laboratory chemicals; manufacture of substances.
- Uses advised against: Not for pharmaceutical, household, or other unapproved uses.
Details of the supplier
- Company: Selleck Chemicals
- TollFree: +1 877 796-6397
- Tel: +1 832 582-8158
- Fax: +1 832 582-8590
Emergency telephone number
- Emergency phone #: +1 832 582-8158
2.1 GHS classification in accordance with 29 CFR 1910 (OSHA HCS):
Not classified as a hazardous substance according to GHS.
2.2 GHS Label elements, including precautionary statements
Hazard Pictogram(s):
None.
Signal Word:
Not applicable
Hazard statement(s):
None.
Precautionary statement(s):
None.
2.3 Other hazards
None.
3.1 Substances
Product name: Stearamide
CAS Number: 124-26-5
PubChem CID: 31292
3.2 Mixtures
Not applicable (pure substance).
4.1 Description of first aid measures
Inhalation: Move to fresh air. Keep at rest in a position comfortable for breathing. Seek medical attention if symptoms persist.
Skin contact: Wash with plenty of soap and water. Remove contaminated clothing. Seek medical attention if irritation develops.
Eye contact: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. Seek medical attention.
Ingestion: Rinse mouth. Do NOT induce vomiting unless directed by medical personnel. Seek medical attention.
4.2 Most important symptoms and effects, both acute and delayed
See Section 11 (Toxicological Information).
4.3 Indication of any immediate medical attention and special treatment needed
Treat symptomatically. Contact a poison control center or physician for severe exposure.
5.1 Extinguishing media
Suitable: Water spray, dry chemical, carbon dioxide (CO2), alcohol-resistant foam.
Unsuitable: None known.
5.2 Specific hazards arising from the substance or mixture
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Advice for firefighters: Wear self contained breathing apparatus for fire fighting if necessary.
5.3 Advice for firefighters
Wear self-contained breathing apparatus (SCBA) and full protective clothing.
Fight fire from upwind. Cool containers with water spray until fire is extinguished.
6.1 Personal precautions, protective equipment and emergency procedures
Wear appropriate personal protective equipment (see Section 8).
Avoid breathing dust/vapor. Ensure adequate ventilation.
Evacuate personnel to safe areas. Keep people away from and upwind of spill.
6.2 Environmental precautions
Prevent product from entering drains, waterways, or soil.
Contain spill with inert absorbent material.
6.3 Methods and materials for containment and cleaning up
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Avoid breathing dust. Environmental precautions: Do not let product enter drains. Methods and materials for containment and cleaning up: Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
SRP: Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in air, soil or water; effects on animal, aquatic and plant life; and conformance with environmental and public health regulations. If it is possible or reasonable use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination.
Product: Offer surplus and non-recyclable solutions to a licensed disposal company. Contaminated packaging: Dispose of as unused product.
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Avoid breathing dust. Environmental precautions: Do not let product enter drains.
Precautions for safe handling: Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. Normal measures for preventive fire protection.
Appropriate engineering controls: Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
SRP: Local exhaust ventilation should be applied wherever there is an incidence of point source emissions or dispersion of regulated contaminants in the work area. Ventilation control of the contaminant as close to its point of generation is both the most economical and safest method to minimize personnel exposure to airborne contaminants. Ensure that the local ventilation moves the contaminant away from the worker.
7.1 Precautions for safe handling
Conditions for safe storage, including any incompatibilities: Keep container tightly closed in a dry and well-ventilated place. Keep in a dry place.
7.2 Conditions for safe storage, including any incompatibilities
Conditions for safe storage, including any incompatibilities: Keep container tightly closed in a dry and well-ventilated place. Keep in a dry place.
Store away from incompatible materials (see Section 10).
[Note: Specific storage temperature not available in public databases. Refer to supplier Certificate of Analysis (COA) for exact storage conditions.]
8.1 Exposure controls
8.1.1 Occupational exposure limits (OEL)
OSHA PEL: Not established.
ACGIH TLV: Not established.
NIOSH REL: Not established.
No occupational exposure limit values are established for this substance.
Use the lowest feasible exposure level (ALARA principle).
8.1.2 Appropriate engineering controls
Use in a well-ventilated area. Chemical fume hood recommended for powder handling.
8.2 Individual protection measures
8.2.1 Eye/face protection
Wear safety glasses with side shields.
8.2.2 Skin protection
Wear protective gloves. Recommended material: Nitrile rubber.
Wear suitable protective clothing (lab coat).
8.2.3 Respiratory protection
Respiratory protection usually not required under normal use with adequate ventilation.
Use N95 respirator for large-scale powder handling.
8.2.4 Thermal hazards
Not applicable.
9.1 Information on basic physical and chemical properties
a) Appearance: Dry Powder; Dry Powder; Large Crystals; Large Crystals
b) Odor: No data available
c) Odor threshold: No data available
d) pH: No data available
e) Melting point/freezing point: 107 °C
f) Initial boiling point and boiling range: BP: 250 °C at 12 mm Hg
g) Flash point: No data available
h) Evaporation rate: No data available
i) Flammability (solid, gas): No data available
j) Upper/lower flammability or explosive limits: No data available
k) Vapor pressure: 0.004 [mmHg]
l) Vapor density: No data available
m) Relative density: No data available
n) Water solubility: Insoluble in water
o) Partition coefficient: n-octanol/water: Log P: No data available
p) Auto-ignition temperature: No data available
q) Decomposition temperature: No data available
r) Viscosity: No data available
s) Explosive properties: No data available
t) Oxidizing properties: No data available
9.2 Other information
10.1 Reactivity
No specific reactivity hazards identified under normal handling conditions.
10.2 Chemical stability
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
No hazardous reactions under normal conditions.
10.4 Conditions to avoid
Avoid heat, sparks, open flames, direct sunlight, and moisture.
10.5 Incompatible materials
Incompatible materials: Strong oxidizing agents, strong acids, bases.
10.6 Hazardous decomposition products
No data available.
See also Section 5 (Fire-fighting measures) for combustion products.
11.1 Information on toxicological effects
Acute toxicity:
No acute toxicity data available.
Skin corrosion/irritation:
No data available.
Serious eye damage/eye irritation:
No data available.
Respiratory or skin sensitization:
No data available.
Germ cell mutagenicity:
No data available.
Carcinogenicity:
No data available.
Reproductive toxicity:
No data available.
Specific target organ toxicity (single exposure):
No data available.
Specific target organ toxicity (repeated exposure):
No data available.
Aspiration hazard:
No data available.
11.2 Additional information
No additional toxicological information available.
12.1 Toxicity
Stearic acid amide's production and use in industry in anti-adhesive agents, lubricants and lubricant additives, plating agents and surface treating agents, processing aids, and viscosity adjustors and use in consumer applications such as in building and construction materials, food packaging, fuels and related products, and plastic and rubber products may result in its release to the environment through various waste streams. If released to air, an estimated vapor pressure of 6.7X10-7 mm Hg at 25 °C indicates stearic acid amide will exist in both the vapor and particulate phases in the atmosphere. Vapor-phase stearic acid amide will be degraded in the atmosphere by reaction with photochemically-produced hydroxyl radicals; the half-life for this reaction in air is estimated to be 14 hours. Particulate-phase stearic acid amide will be removed from the atmosphere by wet and dry deposition. Stearic acid amide does not contain chromophores that absorb at wavelengths >290 nm and, therefore, is not expected to be susceptible to direct photolysis by sunlight. If released to soil, stearic acid amide is expected to have no mobility based upon an estimated Koc of 4.6X10+4. Volatilization from moist soil surfaces is not an important fate process based upon an estimated Henry's Law constant of 1.0X10-6 atm-cu m/mole. Stearic acid amide is not expected to volatilize from dry soil surfaces based upon its estimated vapor pressure. Stearic acid amide reached 62% degradation after 28 days in
12.2 Persistence and degradability
No data available.
12.3 Bioaccumulative potential
No data available.
12.4 Mobility in soil
No data available.
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available.
12.6 Other adverse effects
No other adverse ecological effects identified.
13.1 Waste treatment methods
Waste Treatment Methods: Waste material must be disposed of in accordance with national and local regulations. Leave chemicals in original containers and do not mix with other waste. Handle uncleaned containers in the same manner as the product itself.
14.1 UN number
Not regulated as dangerous goods (research quantities typically exempt).
14.2 UN proper shipping name
Not subject to transport regulations (small quantities for research use).
14.3 Transport hazard class(es)
Not classified as dangerous goods for transport (research quantities).
14.4 Packing group
Not applicable (not regulated as dangerous goods in typical research quantities).
14.5 Environmental hazards
Marine pollutant: No (not classified as environmentally hazardous per GHS).
14.6 Special precautions for user
Transport in original packaging. Ensure containers are tightly sealed.
For bulk or commercial quantities, consult applicable transport regulations (DOT, IATA, IMDG).
14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not applicable.
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
US EPA / TSCA: Subject to EPA TSCA regulations
EU ECHA / REACH: Registered (REACH Active)
SARA 302 Components:
No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components:
This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards:
No SARA Hazards.
Massachusetts Right To Know Components:
No components are subject to the Massachusetts Right to Know Act.
Pennsylvania Right To Know Components:
No components are subject to the Pennsylvania Right to Know Act.
New Jersey Right To Know Components:
No components are subject to the New Jersey Right to Know Act.
California Prop. 65 Components:
This product does not contain any chemicals known to the State of California to cause cancer, birth defects, or any other reproductive harm.
Other regulatory listings:
- The Australian Inventory of Industrial Chemicals: Chemical: Octadecanamide
- FDA Requirements: Stearic acid amide is an indirect food additive for use only as a component of adhesives.
Substances classified as release agents, when migrating from food-packaging material shall include: Stearamide (stearic acid amide)
15.2 Chemical safety assessment
A chemical safety assessment has not been carried out for this substance.
For research-use-only compounds, no CSA is required under REACH Annex I.
Revision Date: 2026/09/09
Further Information: The information provided is believed to be correct but is not exhaustive and should be used only as a guideline based on current knowledge. It does not represent a guarantee of the properties of the product. Selleck Chemicals Corporation and its Affiliates shall not be held liable for any damage resulting from handling or contact with the product.