🛡️ Hazard Overview
- GHS Class: GHS09
- Signal Word: Warning
- Hazard Statements: H400; H410
🧤 PPE Guidelines
- Gloves: Chemical‑resistant gloves suggested
- Eye Protection: Safety goggles suggested
- Respirator: Dust respirator if dust occurs
❄️ Storage
- Storage Temp: -20°C (-4°F) Keep dry
🚑 Emergency First Aid
- For inhalation, skin, eye or ingestion exposure, please refer to full SDS Section 4.
Product identifier
- Product Name: Pyriproxyfen
- Catalog Number: S5798
- CAS Number: 95737-68-1
- IUPAC Name: Pyridine, 2-[1-methyl-2-(4-phenoxyphenoxy)ethoxy]-
Relevant identified uses and uses advised against
- Identified uses: For research and development use only; laboratory chemicals; manufacture of substances.
- Uses advised against: Not for pharmaceutical, household, or other unapproved uses.
Details of the supplier
- Company: Selleck Chemicals
- TollFree: +1 877 796-6397
- Tel: +1 832 582-8158
- Fax: +1 832 582-8590
Emergency telephone number
- Emergency phone #: +1 832 582-8158
2.1 GHS classification in accordance with 29 CFR 1910 (OSHA HCS):
Acute aquatic toxicity: Category 1. H400
Chronic aquatic toxicity: Category 1. H410
2.2 GHS Label elements, including precautionary statements
Hazard Pictogram(s):
![]()
Signal Word:
Warning
Hazard statement(s):
H400: Very toxic to aquatic life
H410: Very toxic to aquatic life with long lasting effects
Precautionary statement(s):
Prevention:
P273: Avoid release to the environment.
Response:
P391: Collect spillage.
Disposal:
P501: P501 Dispose of contents/ container to an approved waste disposal plant.
2.3 Other hazards
None.
3.1 Substances
Product name: Pyriproxyfen
CAS Number: 95737-68-1
PubChem CID: 91753
Molecular formula: C20H19NO3
Molecular weight: 321.4 g/mol
IUPAC name: 2-[1-(4-phenoxyphenoxy)propan-2-yloxy]pyridine
3.2 Mixtures
Not applicable (pure substance).
4.1 Description of first aid measures
Inhalation: Fresh air, rest.
Skin contact: Rinse and then wash skin with water and soap.
Eye contact: Rinse with plenty of water (remove contact lenses if easily possible).
Ingestion: Rinse mouth.
4.2 Most important symptoms and effects, both acute and delayed
See Section 11 (Toxicological Information).
4.3 Indication of any immediate medical attention and special treatment needed
Treat symptomatically. Contact a poison control center or physician for severe exposure.
5.1 Extinguishing media
Suitable: Water spray, dry chemical, carbon dioxide (CO2), alcohol-resistant foam.
Unsuitable: None known.
5.2 Specific hazards arising from the substance or mixture
Use water spray, powder, foam, carbon dioxide.
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide.
Advice for firefighters: Wear self contained breathing apparatus for fire fighting if necessary.
5.3 Advice for firefighters
Wear self-contained breathing apparatus (SCBA) and full protective clothing.
Fight fire from upwind. Cool containers with water spray until fire is extinguished.
Flash point: 119 °C c.c.
6.1 Personal precautions, protective equipment and emergency procedures
Wear appropriate personal protective equipment (see Section 8).
Avoid breathing dust/vapor. Ensure adequate ventilation.
Evacuate personnel to safe areas. Keep people away from and upwind of spill.
6.2 Environmental precautions
Prevent product from entering drains, waterways, or soil.
Contain spill with inert absorbent material.
6.3 Methods and materials for containment and cleaning up
Personal protection: particulate filter respirator adapted to the airborne concentration of the substance. Do NOT let this chemical enter the environment. Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting. Carefully collect remainder. Then store and dispose of according to local regulations.
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. Methods and materials for containment and cleaning up: Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
Personal protection: particulate filter respirator adapted to the airborne concentration of the substance. Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting. Carefully collect remainder. Then store and dispose of according to local regulations. Do NOT wash away into sewer.
SRP: Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in air, soil or water; effects on animal, aquatic and plant life; and conformance with environmental and public health regulations. If it is possible or reasonable use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination.
Product: Offer surplus and non-recyclable solutions to a licensed disposal company; Contaminated packaging: Dispose of as unused product.
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.
Precautions for safe handling: Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed.
Appropriate engineering controls: Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
SRP: Local exhaust ventilation should be applied wherever there is an incidence of point source emissions or dispersion of regulated contaminants in the work area. Ventilation control of the contaminant as close to its point of generation is both the most economical and safest method to minimize personnel exposure to airborne contaminants. Ensure that the local ventilation moves the contaminant away from the worker.
7.1 Precautions for safe handling
Separated from food and feedstuffs. Well closed. Store in an area without drain or sewer access.
Keep container tightly closed in a dry and well-ventilated place.
Provision to contain effluent from fire extinguishing. Separated from food and feedstuffs. Well closed.
7.2 Conditions for safe storage, including any incompatibilities
Separated from food and feedstuffs. Well closed. Store in an area without drain or sewer access.
Keep container tightly closed in a dry and well-ventilated place.
Provision to contain effluent from fire extinguishing. Separated from food and feedstuffs. Well closed.
Store away from incompatible materials (see Section 10).
[Note: Specific storage temperature not available in public databases. Refer to supplier Certificate of Analysis (COA) for exact storage conditions.]
Store in original container. Keep upright to prevent leakage.
8.1 Exposure controls
8.1.1 Occupational exposure limits (OEL)
OSHA PEL: Not established.
ACGIH TLV: Not established.
NIOSH REL: Not established.
No occupational exposure limit values are established for this substance.
Use the lowest feasible exposure level (ALARA principle).
8.1.2 Appropriate engineering controls
Use in a well-ventilated area. Chemical fume hood recommended for powder handling.
8.2 Individual protection measures
8.2.1 Eye/face protection
Wear safety glasses with side shields.
8.2.2 Skin protection
Wear protective gloves. Recommended material: Nitrile rubber.
Wear suitable protective clothing (lab coat).
8.2.3 Respiratory protection
Respiratory protection usually not required under normal use with adequate ventilation.
Use N95 respirator for large-scale powder handling.
8.2.4 Thermal hazards
Not applicable.
9.1 Information on basic physical and chemical properties
a) Appearance: Pale yellow liquid; Solidifies on standing; mp = 49.7 deg C; [Merck Index] Colorless solid; mp = 45-47 deg C; [ICSC] Colorless solid or pale yellow liquid; mp = 45-47 deg C; [HSDB] White crystalline solid; [MSDSonline]
b) Odor: No data available
c) Odor threshold: No data available
d) pH: No data available
e) Melting point/freezing point: 47 °C
f) Initial boiling point and boiling range: 318 °C
g) Flash point: 119 °C c.c.
h) Evaporation rate: No data available
i) Flammability (solid, gas): No data available
j) Upper/lower flammability or explosive limits: No data available
k) Vapor pressure: 0.00000218 [mmHg]
l) Vapor density: No data available
m) Relative density: 1.24 at 25 °C
n) Water solubility: In hexane 400, methanol 200, xylene 500 (all g/kg at 20-25 °C)
o) Partition coefficient: n-octanol/water: Log P (n-octanol/water): 4.8
p) Auto-ignition temperature: No data available
q) Decomposition temperature: No data available
r) Viscosity: No data available
s) Explosive properties: No data available
t) Oxidizing properties: No data available
9.2 Other information
Topological Polar Surface Area (TPSA): 40.6 Ų
Complexity: 338
10.1 Reactivity
No specific reactivity hazards identified under normal handling conditions.
10.2 Chemical stability
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
No hazardous reactions under normal conditions.
10.4 Conditions to avoid
Avoid heat, sparks, open flames, direct sunlight, and moisture.
Avoid strong oxidizing agents, strong acids, and strong bases.
10.5 Incompatible materials
Incompatible materials: Strong oxidizing agents
10.6 Hazardous decomposition products
Thermal decomposition may produce: Carbon monoxide (CO), Carbon dioxide (CO₂), Nitrogen oxides (NOx).
See also Section 5 (Fire-fighting measures) for combustion products.
11.1 Information on toxicological effects
Acute toxicity:
No acute toxicity data available.
Skin corrosion/irritation:
No data available.
Serious eye damage/eye irritation:
No data available.
Respiratory or skin sensitization:
No data available.
Germ cell mutagenicity:
No data available.
Carcinogenicity:
No data available.
Reproductive toxicity:
No data available.
Specific target organ toxicity (single exposure):
No data available.
Specific target organ toxicity (repeated exposure):
No data available.
Aspiration hazard:
No data available.
11.2 Additional information
Carcinogen classification:
No indication of carcinogenicity to humans (not listed by IARC).
Exposure routes:
The substance can be absorbed into the body by ingestion and by inhalation of dust.
Signs and symptoms of exposure:
Cough.
No acute symptoms expected.
Redness.
No acute symptoms expected.
Data source: Hazardous Substances Data Bank (HSDB) via PubChem.
12.1 Toxicity
LC50; Species: Daphnia carinata sensu lato /Cladoceran/; Concentration: 0.08 ppm for 48 hr /Conditions of bioassay not specified/
LC50; Species: Leander tenuicornis (shrimp); Concentration: 0.098 ppm for 96 hr /Conditions of bioassay not specified/
EC50; Species: Daphnia magna (Water flea) age 6-7 days female; Conditions: freshwater, renewal, 20 °C; Concentration: 149 ug/L for 60 hr; Effect: genetics, increased 2-domain hemoglobin mRNA /formulation/
EC50; Species: Daphnia magna (Water Flea) age >13 day, mature organism; Conditions: freshwater, renewal, 20 °C; Concentration: 0.0557 ug/L for 5 days; Effect: population, change sex ratio /formulation/
For more Ecotoxicity Values (Complete) data for PYRIPROXYFEN (9 total), please visit the HSDB record page.
/AQUATIC SPECIES/ ... Several candidate transcription factors were cloned from the water flea Daphnia pulex and evaluated for activation by methyl farnesoate. One of the factors evaluated, the complex of two bHLH-PAS proteins, dappuMet and SRC, activated a reporter gene in response to methyl farnesoate. Several juvenoid compounds were definitively evaluated for their ability to activate this receptor complex (methyl farnesoate receptor, MfR) in vitro and stimulate male sex determination in vivo. Potency to activate the MfR correlated to potency to stimulate male sex determination of offspring (pyriproxyfen>methyl farnesoate>methoprene, kinoprene). Daphnids were exposed to concentrations of pyriproxyfen and physiologic responses
12.2 Persistence and degradability
No data available.
12.3 Bioaccumulative potential
Log P (n-octanol/water): 4.8
Potential for bioaccumulation exists (Log P > 3).
12.4 Mobility in soil
No data available.
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available.
12.6 Other adverse effects
This substance is classified as hazardous to the aquatic environment.
13.1 Waste treatment methods
Waste Treatment Methods: Waste material must be disposed of in accordance with national and local regulations. Leave chemicals in original containers and do not mix with other waste. Handle uncleaned containers in the same manner as the product itself.
14.1 UN number
Not regulated as dangerous goods (research quantities typically exempt).
14.2 UN proper shipping name
Not subject to transport regulations (small quantities for research use).
14.3 Transport hazard class(es)
Class 9
14.4 Packing group
Packing group III
14.5 Environmental hazards
Marine pollutant: Yes (classified as environmentally hazardous per GHS).
14.6 Special precautions for user
Transport in original packaging. Ensure containers are tightly sealed.
For bulk or commercial quantities, consult applicable transport regulations (DOT, IATA, IMDG).
14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not applicable.
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
US EPA / TSCA: Subject to EPA TSCA regulations
EU ECHA / REACH: Registered (REACH Active)
SARA 302 Components:
No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components:
This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards:
Environmental hazard
Massachusetts Right To Know Components:
This material contains components subject to the Massachusetts Right to Know Act. See Section 2 for hazard classification.
Pennsylvania Right To Know Components:
This material contains components subject to the Pennsylvania Right to Know Act. See Section 2 for hazard classification.
New Jersey Right To Know Components:
This material contains components subject to the New Jersey Right to Know Act. See Section 2 for hazard classification.
California Prop. 65 Components:
This product does not contain any chemicals known to the State of California to cause cancer, birth defects, or any other reproductive harm.
Other regulatory listings:
- EFSA Legal Basis: Commission Regulation No 844/2012
- Safe Drinking Water Act: Pyriproxyfen is listed in the dataset of EPA Human Health Benchmarks for Pesticides under the Safe Drinking Water Act (40 eCFR 141)
- Status Regulation (EC): 2010/39/EU, Reg. (EU) 2018/1796, Reg. (EU) 2019/1589, Reg. (EU) 2020/968, Reg. (EU) No 540/2011
- FIFRA Requirements: Tolerances are established for residues of pyriproxyfen, including its metabolites and degradates, in or on the commodities in the following table. Compliance with the tolerance levels specified is determined by measuring only pyriproxyfen, 2-[1-methyl-2-(4-phenoxyphenoxy) ethoxy]pyridine, in or on
15.2 Chemical safety assessment
A chemical safety assessment has not been carried out for this substance.
For research-use-only compounds, no CSA is required under REACH Annex I.
Revision Date: 2026/09/09
Further Information: The information provided is believed to be correct but is not exhaustive and should be used only as a guideline based on current knowledge. It does not represent a guarantee of the properties of the product. Selleck Chemicals Corporation and its Affiliates shall not be held liable for any damage resulting from handling or contact with the product.