Clinical Trials
Multiple clinical trials have evaluated KA2507 in Phase 1 and Phase 2 settings for adult solid tumors and advanced biliary tract cancer. A completed Phase 1 clinical trial sponsored by Karus Therapeutics Limited evaluated the safety, tolerability, pharmacokinetics, and pharmacodynamics of the drug in adults with solid tumors. Meanwhile, a Phase 2 clinical trial investigating selective HDAC6 inhibition in pretreated advanced biliary tract cancer, sponsored by Karus Therapeutics Limited in collaboration with University College London, was withdrawn.
| NCT Number | Recruitment | Conditions | Sponsor/Collaborators | Start Date | Phases |
|---|---|---|---|---|---|
| NCT04186156 | WITHDRAWN | Biliary Tract Cancer |
Karus Therapeutics Limited |
2020-03-05 | PHASE2 |
| NCT03008018 | COMPLETED | Solid Tumor, Adult |
Karus Therapeutics Limited |
2017-08-07 | PHASE1 |
| NCT04186156 | Withdrawn | Biliary Tract Cancer |
Karus Therapeutics Limited|University College London |
2020-03-05 | Phase 2 |
| NCT03008018 | Completed | Solid Tumor Adult |
Karus Therapeutics Limited |
2017-08-07 | Phase 1 |
(data from https://clinicaltrials.gov, updated on 2021-02-03)
Compliance for Clinical Use
Mechanism and Biochemical Profile
Appendix RUO and cGMP Quality Standards
| Quality Dimension | RUO (Research Use Only) | cGMP (Current Good Manufacturing Practice) |
|---|---|---|
| Clinical Applicability | Prohibited in human clinical trials or medical diagnostics. | Mandatory for human clinical trials (Phase I–III) and therapies. |
| Regulatory Status | Non-regulated grade; exempt from drug manufacturing laws. | Legally enforced by health authorities (e.g., FDA, EMA, NMPA). |
| Facility Environment | Unclassified analytical or research laboratories. | Validated Cleanrooms (ISO Class 5–8) with continuous monitoring. |
| Quality Control | Basic purity and activity testing. | Rigorous safety release testing (Sterility, Endotoxin, Mycoplasma). |
| Process Validation | Basic equipment calibration; no process validation required. | Full qualification (IQ/OQ/PQ) and complete batch records. |
| Quality Assurance | Vendor self-declared without required formal QMS. | Mandatory QA/QC unit, Change Control, CAPA, and vendor audits. |
| Regulatory Impact | High risk of IND rejection if used as a critical raw material. | Required for IND/NDA filings, supported by Drug Master Files (DMF). |
Footnotes
Regulatory Note: Governed by FDA (21 CFR Parts 210/211/312), EMA (EudraLex Vol 4), ICH Guidelines (E6/Q7/Q9/Q10), and compendial standards (USP <71>/<85>/<1043>).