Download SDS
CAS No.: 60-35-5
Check the Acetamide product page for in-depth specifications, including solubility, stock solutions, MOA, and working concentrations.

Quick Safety Reference

🛡️ Hazard Overview

  • GHS Class: GHS08
  • Signal Word: Warning
  • Hazard Statements: H316; H320; H351; H361

🧤 PPE Guidelines

  • Gloves: Chemical‑resistant gloves suggested
  • Eye Protection: Safety goggles suggested
  • Respirator: Dust respirator if dust occurs

❄️ Storage

  • Storage Temp: -20°C (-4°F) Keep dry

🚑 Emergency First Aid

  • For inhalation, skin, eye or ingestion exposure, please refer to full SDS Section 4.

GHS 16 Safety Standard Sections

Product identifier

  • Product Name: Acetamide
  • Catalog Number: S6011
  • CAS Number: 60-35-5
  • IUPAC Name: Acetamide

Relevant identified uses and uses advised against

  • Identified uses: For research and development use only; laboratory chemicals; manufacture of substances.
  • Uses advised against: Not for pharmaceutical, household, or other unapproved uses.

Details of the supplier

  • Company: Selleck Chemicals
  • TollFree: +1 877 796-6397
  • Tel: +1 832 582-8158
  • Fax: +1 832 582-8590

Emergency telephone number

  • Emergency phone #: +1 832 582-8158

2.1 GHS classification in accordance with 29 CFR 1910 (OSHA HCS):
Skin irritation: Category 3. H316
Eye irritation: Category 2. H320
Carcinogenicity: Category 2. H351
Reproductive toxicity: Category 2. H361

2.2 GHS Label elements, including precautionary statements
Hazard Pictogram(s):
GHS08
Signal Word:
Warning
Hazard statement(s):
H316: Causes mild skin irritation
H320: Causes eye irritation
H351: Suspected of causing cancer
H361: Suspected of damaging fertility or the unborn child
Precautionary statement(s):
Prevention:
P203: Obtain, read and follow all safety instructions before use.
P264+P265: Wash hands thoroughly after handling. Do not touch eyes.
P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
Response:
P305+P351: IF IN EYES: Rinse cautiously with water for several minutes.
P318: if exposed or concerned, get medical advice.
P332+P317: If skin irritation occurs: Get medical help.
P337+P317: If eye irritation persists: Get medical help.
P338: Remove contact lenses, if present and easy to do. Continue rinsing.
Storage:
P405: Store locked up.
Disposal:
P501: P501 Dispose of contents/ container to an approved waste disposal plant.

2.3 Other hazards
None.

3.1 Substances
Product name: Acetamide
CAS Number: 60-35-5
PubChem CID: 178
Molecular formula: C2H5NO
Molecular weight: 59.07 g/mol
IUPAC name: acetamide

3.2 Mixtures
Not applicable (pure substance).

4.1 Description of first aid measures
Inhalation: Fresh air, rest.
Skin contact: Remove contaminated clothes. Rinse skin with plenty of water or shower.
Eye contact: First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Ingestion: Rinse mouth. Refer for medical attention .

4.2 Most important symptoms and effects, both acute and delayed
See Section 11 (Toxicological Information).

4.3 Indication of any immediate medical attention and special treatment needed
Treat symptomatically. Contact a poison control center or physician for severe exposure.

5.1 Extinguishing media
Suitable: Water spray, dry chemical, carbon dioxide (CO2), alcohol-resistant foam.
Unsuitable: None known.

5.2 Specific hazards arising from the substance or mixture
Fires involving this material can be controlled with a dry chemical, carbon dioxide or Halon extinguisher. (NTP, 1992)
Use water spray, powder.
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide.
Advice for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.
Use dry chemical, carbon dioxide, water spray, or alcohol foam extinguishers. ... If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Notify local health and fire officials and pollution control agencies. From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors, or shows any signs of deforming), withdraw immediately to a secure position.
The only respirators recommended for firefighting are self-contained breathing apparatuses that have full face-pieces and are operated in a pressure-demand or other positive-pressure mode.

5.3 Advice for firefighters
Wear self-contained breathing apparatus (SCBA) and full protective clothing.
Fight fire from upwind. Cool containers with water spray until fire is extinguished.

6.1 Personal precautions, protective equipment and emergency procedures
Wear appropriate personal protective equipment (see Section 8).
Avoid breathing dust/vapor. Ensure adequate ventilation.
Evacuate personnel to safe areas. Keep people away from and upwind of spill.

6.2 Environmental precautions
Prevent product from entering drains, waterways, or soil.
Contain spill with inert absorbent material.

6.3 Methods and materials for containment and cleaning up
Personal protection: P2 filter respirator for harmful particles. Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting. Carefully collect remainder. Then store and dispose of according to local regulations.
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Methods and materials for containment and cleaning up: Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
Evacuate persons not wearing protective equipment from area of spill or leak until cleanup is complete. Remove all ignition sources. Collect powdered material in the most convenient and safe manner and deposit in sealed containers. Ventilate area after cleanup is complete. Material is very water soluble and hydrolyzes slowly to ammonia and acetate salts. May be removed from alkaline solutions with adsorbent carbon. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters.
PRECAUTIONS FOR "CARCINOGENS": A high-efficiency particulate arrestor (HEPA) or charcoal filters can be used to minimize amt of carcinogen in exhausted air ventilated safety cabinets, lab hoods, glove boxes or animal rooms ... Filter housing that is designed so that used filters can be transferred into plastic bag without contaminating maintenance staff is avail commercially. Filters should be placed in plastic bags immediately after removal ... The plastic bag should be sealed immediately ... The sealed bag should be labelled properly ... Waste liquids ... should be placed or collected in proper containers for disposal. The lid should be secured & the bottles properly labelled. Once filled, bottles should be placed in plastic bag, so that outer surface ... is not contaminated ... The plastic bag should also be sealed & labelled. ... Broken glassware ... should be decontaminated by solvent extraction, by chemical destruction, or in specially designed incinerators. /Chemical Carcinogens/
SRP: Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in air, soil or water; effects on animal, aquatic and plant life; and conformance with environmental and public health regulations. If it is possible or reasonable use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination.
SRP: Wastewater from contaminant suppression, cleaning of protective clothing/equipment, or contaminated sites should be contained and evaluated for subject chemical or decomposition product concentrations. Concentrations shall be lower than applicable environmental discharge or disposal criteria. Alternatively, pretreatment and/or discharge to a permitted wastewater treatment facility is acceptable only after review by the governing authority and assurance that "pass through" violations will not occur. Due consideration shall be given to remediation worker exposure (inhalation, dermal and ingestion) as well as fate during treatment, transfer and disposal. If it is not practicable to manage the chemical in this fashion, it must be evaluated in accordance with EPA 40 CFR Part 261, specifically Subpart B, in order to determine the appropriate local, state and federal requirements for disposal.
Product: Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber; Contaminated packaging: Dispose of as unused product.
PRECAUTIONS FOR "CARCINOGENS": There is no universal method of disposal that has been proved satisfactory for all carcinogenic compounds & specific methods of chem destruction ... published have not been tested on all kinds of carcinogen-containing waste. ... summary of avail methods & recommendations ... /given/ must be treated as guide only. /Chemical Carcinogens/
For more Disposal Methods (Complete) data for ACETAMIDE (8 total), please visit the HSDB record page.
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Precautions for safe handling: Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed.
PRECAUTIONS FOR "CARCINOGENS": Smoking, drinking, eating, storage of food or of food & beverage containers or utensils, & the application of cosmetics should be prohibited in any laboratory. All personnel should remove gloves, if worn, after completion of procedures in which carcinogens have been used. They should ... wash ... hands, preferably using dispensers of liq detergent, & rinse ... thoroughly. Consideration should be given to appropriate methods for cleaning the skin, depending on nature of the contaminant. No standard procedure can be recommended, but the use of organic solvents should be avoided. Safety pipettes should be used for all pipetting. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": In animal laboratory, personnel should remove their outdoor clothes & wear protective suits (preferably disposable, one-piece & close-fitting at ankles & wrists), gloves, hair covering & overshoes. ... clothing should be changed daily but ... discarded immediately if obvious contamination occurs ... /also,/ workers should shower immediately. In chemical laboratory, gloves & gowns should always be worn ... however, gloves should not be assumed to provide full protection. Carefully fitted masks or respirators may be necessary when working with particulates or gases, & disposable plastic aprons might provide addnl protection. If gowns are of distinctive color, this is a reminder that they should not be worn outside of lab. /Chemical Carcinogens/
For more Preventive Measures (Complete) data for ACETAMIDE (14 total), please visit the HSDB record page.

7.1 Precautions for safe handling
SMALL SPILLS AND LEAKAGE: If you spill this chemical, you should dampen the solid spill material with water, then transfer the dampened material to a suitable container. Use absorbent paper dampened with water to pick up any remaining material. Seal your contaminated clothing and the absorbent paper in a vapor-tight plastic bag for eventual disposal. Wash all contaminated surfaces with a strong soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned.
STORAGE PRECAUTIONS: You should keep this material in a tightly-closed container under an inert atmosphere, and store it at refrigerated temperatures. (NTP, 1992)
Dry. Well closed.
Keep container tightly closed in a dry and well-ventilated place. Moisture sensitive.
Appropriate engineering controls: Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Should be stored in a cool, well-ventilated area. Store in a dry area away from water because of deliquescent properties. Sources of ignition, such as smoking and open flames, are prohibited where this chemical is used, handled, or stored in a manner that could create a potential fire explosion hazard.
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practical to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. /Chemical Carcinogens/

7.2 Conditions for safe storage, including any incompatibilities
Dry. Well closed.
Keep container tightly closed in a dry and well-ventilated place. Moisture sensitive.
Appropriate engineering controls: Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Should be stored in a cool, well-ventilated area. Store in a dry area away from water because of deliquescent properties. Sources of ignition, such as smoking and open flames, are prohibited where this chemical is used, handled, or stored in a manner that could create a potential fire explosion hazard.
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practical to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. /Chemical Carcinogens/
Store away from incompatible materials (see Section 10).
[Note: Specific storage temperature not available in public databases. Refer to supplier Certificate of Analysis (COA) for exact storage conditions.]

8.1 Exposure controls
8.1.1 Occupational exposure limits (OEL)
carcinogen category: 3.

8.1.2 Appropriate engineering controls
Use in a well-ventilated area. Chemical fume hood recommended for powder handling.

8.2 Individual protection measures
8.2.1 Eye/face protection
Wear chemical safety goggles.
8.2.2 Skin protection
Wear protective gloves. Recommended material: Nitrile rubber.
Wear suitable protective clothing (lab coat).
8.2.3 Respiratory protection
Respiratory protection usually not required under normal use with adequate ventilation.
Use N95 respirator for large-scale powder handling.
8.2.4 Thermal hazards
Not applicable.

9.1 Information on basic physical and chemical properties
a) Appearance: Acetamide appears as colorless crystals with a mousy odor (NTP, 1999). Low toxicity.
b) Odor: Odorless when pure, but frequently has a mousy odor
c) Odor threshold: No data available
d) pH: No data available
e) Melting point/freezing point: 180.1 °F (NTP, 1992)
f) Initial boiling point and boiling range: 430 °F at 760 mmHg (NTP, 1992)
g) Flash point: No data available
h) Evaporation rate: No data available
i) Flammability (solid, gas): No data available
j) Upper/lower flammability or explosive limits: No data available
k) Vapor pressure: 1 mmHg at 149 °F (NTP, 1992)
l) Vapor density: No data available
m) Relative density: 1.159 at 68 °F (NTP, 1992) - Denser than water; will sink
n) Water solubility: Very soluble (greater than or equal to 100 mg/mL at 72 °F) (NTP, 1992)
o) Partition coefficient: n-octanol/water: Log P (n-octanol/water): -0.9
p) Auto-ignition temperature: No data available
q) Decomposition temperature: No data available
r) Viscosity: 2.182 centipose (91.1 °C); 1.461 centipose (111.8 °C); 1.056 centipose (131.7 °C)
s) Explosive properties: No data available
t) Oxidizing properties: No data available

9.2 Other information
Topological Polar Surface Area (TPSA): 43.1 Ų
Complexity: 33

10.1 Reactivity
No specific reactivity hazards identified under normal handling conditions.

10.2 Chemical stability
Stable under recommended storage conditions.

10.3 Possibility of hazardous reactions
No hazardous reactions under normal conditions.

10.4 Conditions to avoid
Avoid heat, sparks, open flames, direct sunlight, and moisture.
Avoid strong oxidizing agents, strong acids, and strong bases.

10.5 Incompatible materials
Incompatible materials: Strong oxidizing agents, strong acids, strong bases, strong reducing agents.
Reacts with strong acids, such as hydrochloric, sulfuric, and nitric; strong oxidizers; strong bases; strong reducing agents; ammonia, isocyanates, phenols, cresols. Contact with water causes slow hydrolyzation to ammonia and acetate salts.

10.6 Hazardous decomposition products
Thermal decomposition may produce: Carbon monoxide (CO), Carbon dioxide (CO₂), Nitrogen oxides (NOx).
See also Section 5 (Fire-fighting measures) for combustion products.

11.1 Information on toxicological effects
Acute toxicity:
No acute toxicity data available.
Skin corrosion/irritation:
No data available.
Serious eye damage/eye irritation:
No data available.
Respiratory or skin sensitization:
No data available.
Germ cell mutagenicity:
No data available.
Carcinogenicity:
Suspected of causing cancer (H351).
Reproductive toxicity:
Suspected of damaging fertility or the unborn child (H361).
Specific target organ toxicity (single exposure):
No data available.
Specific target organ toxicity (repeated exposure):
No data available.
Aspiration hazard:
No data available.

11.2 Additional information
Carcinogen classification:
Acetamide
Group 2B: Possibly carcinogenic to humans
Volume 7: (1974) Some Anti-thyroid and Related Substances, Nitrofurans and Industrial Chemicals
Volume Sup 7: Overall Evaluations of Carcinogenicity: An Updating of IARC Monographs Volumes 1 to 42, 1987; 440 pages; ISBN 92-832-1411-0 (out of print)
Volume 71: (1999) Re-evaluation of Some Organic Chemicals, Hydrazine and Hydrogen Peroxide (Part 1, Part 2, Part 3)
1999
1998
2B, possibly carcinogenic to humans. (L135)
Exposure routes:
The substance can be absorbed into the body by inhalation of its aerosol.
Signs and symptoms of exposure:
Redness. Pain.
Redness. Pain.
Data source: Hazardous Substances Data Bank (HSDB) via PubChem.

12.1 Toxicity
/AQUATIC SPECIES/ ... In rainbow trout, increase in sperm motility parameters (VAP and MOT) were observed in the presence of acetamide, an inhibitor for beta-N-Acetylglucosaminidase (beta-NAGase). In contrast, sperm motility parameters (VCL, VSL, VAP, MOT, and PRG) were reduced on the Siberian sturgeon in the presence of acetamide. The inhibition of the activity of beta-NAGase in rainbow trout spermatozoa was led to a reduction in the number of fertilized eggs from 79% to 40%, whereas in sturgeon no change was observed in fertilization. Moreover, inhibition of beta-NAGase in both spermatozoa and eggs of trout and sturgeon resulted in significant decrease in fertilization rate from 79% to 1% in rainbow trout and from 84% to 12% in Siberian sturgeon. ...
/AQUATIC SPECIES/ The toxicity threshold using the cell multiplication inhibition test was determined for pseudomonas putida (bacteria), scendesmus quadricauda (green algae) and entosiphon sulcatum (protozoa). Test based on principle that dissolved toxic water ingredients will inhibit multiplication of test organisms as compared to culture free from such influence. Acetamide exhibited a selective damaging action on entosiphon sulcatum.
Acetamide's production and use as a solvent and plasticizer, as a solubilizer and in organic synthesis may result in its release to the environment through various waste streams. Acetamide has been detected near the center of the Milky Way galaxy, on the surface of a comet and as a mineral in was

12.2 Persistence and degradability
No data available.

12.3 Bioaccumulative potential
Log P (n-octanol/water): -0.9
Low potential for bioaccumulation (Log P < 3).

12.4 Mobility in soil
No data available.

12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available.

12.6 Other adverse effects
No other adverse ecological effects identified.

13.1 Waste treatment methods
Waste Treatment Methods: Waste material must be disposed of in accordance with national and local regulations. Leave chemicals in original containers and do not mix with other waste. Handle uncleaned containers in the same manner as the product itself.

14.1 UN number
Not regulated as dangerous goods (research quantities typically exempt).

14.2 UN proper shipping name
Not subject to transport regulations (small quantities for research use).

14.3 Transport hazard class(es)
Not classified as dangerous goods for transport (research quantities).

14.4 Packing group
Not applicable (not regulated as dangerous goods in typical research quantities).

14.5 Environmental hazards
Marine pollutant: No (not classified as environmentally hazardous per GHS).

14.6 Special precautions for user
Transport in original packaging. Ensure containers are tightly sealed.
For bulk or commercial quantities, consult applicable transport regulations (DOT, IATA, IMDG).

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not applicable.

15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
US EPA / TSCA: Subject to EPA TSCA regulations
EU ECHA / REACH: Registered (REACH Active)

SARA 302 Components:
No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components:
This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards:
Acute (short-term) health hazard
Chronic (long-term) health hazard

Massachusetts Right To Know Components:
This material contains components subject to the Massachusetts Right to Know Act. See Section 2 for hazard classification.
Pennsylvania Right To Know Components:
This material contains components subject to the Pennsylvania Right to Know Act. See Section 2 for hazard classification.
New Jersey Right To Know Components:
This material contains components subject to the New Jersey Right to Know Act. See Section 2 for hazard classification.

California Prop. 65 Components:
This product does not contain any chemicals known to the State of California to cause cancer, birth defects, or any other reproductive harm.

Other regulatory listings:
- The Australian Inventory of Industrial Chemicals: Chemical: Acetamide
- California Safe Cosmetics Program (CSCP) Reportable Ingredient: Hazard Traits - Carcinogenicity; Dermatotoxicity Authoritative List - CA TACs; IARC Carcinogens - 2B; Prop 65 Report - regardless of intended function of ingredient in the product
- New Jersey Worker and Community Right to Know Act: The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)
- Atmospheric Standards: This action promulgates standards of performance for equipment leaks of Volatile Organic Compounds (VOC) in the Synthetic Organic Chemical Manufacturing Industry (SOCMI). The intended effect of these standards is to require all newly constructed, modified, and reconstructed SOCMI process units to us
- CERCLA Reportable Quantities: Persons in charge of vessels or facilities are required to notify the National Response Center (NRC) immediately, when there is a release of this designated hazardous substance, in an amount equal to or greater than its reportable quantity of 100 lb or 45.4 kg. The toll free number of the NRC is (80

15.2 Chemical safety assessment
A chemical safety assessment has not been carried out for this substance.
For research-use-only compounds, no CSA is required under REACH Annex I.

Revision Date: 2026/09/09
Further Information: The information provided is believed to be correct but is not exhaustive and should be used only as a guideline based on current knowledge. It does not represent a guarantee of the properties of the product. Selleck Chemicals Corporation and its Affiliates shall not be held liable for any damage resulting from handling or contact with the product.

Note: Technical data last updated: Sep 1, 2026.